our solutions by application
Chemical Plants
1. Sandblast to obtain a surface profile of 1 to 1.5 mils complying with the standard SSPC-SP6 (commercial blast).
2. Apply two coats of one component anti-corrosion primer MC-4390 to obtain a dry film thickness of 6 mils.
3. Topcoat with Glass-Guard polyurethane 2800 Series for a dry film thickness of 2 mils.